MavSeal · Fast-Cure Polyurea Topcoat

MavSeal RCU Fast-Cure Polyurea Topcoat

MavSeal RCU is a two-component, high-gloss polyurea coating designed for industrial and commercial applications. MavSeal RCU is designed for use as a fast-curing, UV-stable topcoat and is an excellent topcoat for decorative flake and decorative quartz applications. With MavTints liquid color packs, MavSeal RCU can be pigmented to many colors.

MavSeal RCU: Fast-Cure Polyurea Topcoat

MavSeal RCU is a high-build polyurea applied in one 16 mil coat over a broadcast at 100 sq. ft./gal. per coat. A typical system is primer plus 2 coats, or an aggregate, color quartz or flake broadcast with MavSeal RCU as the topcoat.

Pot life is 13 minutes at 77°F, but material that gels on top in the pail is not lost: the underlying material remains usable up to 6 hours after mixing. Once applied at proper mil thickness, MavSeal RCU cures like a polyaspartic. The maximum recoat window is 24 hours at 70°F; if it is missed, the coating must be sanded before recoating.

Where it fits: MavSeal RCU is a topcoat over Maverick flooring systems: prime the concrete with MavPrime EP or MavPrime MVT, or install over a Maverick polyurethane flooring system, and never apply it directly to concrete.

Every figure on this page is taken from the MavSeal RCU product data sheet. Open the product data sheet for the complete application instructions.

Features and Benefits

  • High build, one coat over broadcast
  • Full gloss finish
  • Excellent UV stability
  • Extended working time: underlying material remains usable up to 6 hours after mixing
  • Seamless, monolithic application
  • Durable finish, chemical resistant
  • Available in clear and a wide array of colors

Where MavSeal RCU Is Used

  • Warehousing and manufacturing facilities
  • Chemical processing plants
  • Laboratories, hospitals, healthcare facilities
  • Stadiums and other entertainment venues
  • Educational and institutional facilities
  • Cafeterias, kitchens, storefronts, aisles
  • Bathrooms, showers
  • Topcoat over Maverick flooring systems

Read Before Specifying

  • MavSeal RCU must not be applied directly to bare concrete; always prime or install over a Maverick flooring system.
  • Confirm product performance in the specific chemical environment prior to use.
  • Prepare the substrate according to the surface preparation requirements.
  • Do not apply to slabs on grade without a heavy, unruptured vapor barrier, or where moisture/MVT is present.
  • Do not apply at a temperature or thickness not recommended.
  • For industrial/commercial use. Installation by trained personnel only.
  • Do not allow materials to freeze.

MavSeal RCU Published Data

Values below are reproduced from the current MavSeal RCU product data sheet dated 10/01/2026. Request project-specific values through the data sheet.

MavSeal RCU physical data, as published
PropertyValue
Components2 (Part A Resin & Part B Hardener)
Generic TypeHigh-build polyurea coating
ColorClear; pigmentable with MavTints
FinishHigh gloss
Mix Ratio (by volume)2 Part A : 1 Part B
Curing MechanismChemical reaction between components
Pot Life13 minutes (@77°F)
Bucket Working TimeUp to 6 hours after mixing
Air Temperature50° – 80°F (10° – 27°C)
Surface TemperatureMinimum 5°F above dew point
Storage Temperature65° – 80°F (18° – 27°C)
MavSeal RCU physical properties and test methods
PropertyTest MethodResult
Compressive StrengthASTM C57910,900 psi
Tensile StrengthASTM D6385,000 psi
Flexural StrengthASTM C5804,550 psi
Hardness, Shore DASTM D224060 – 70
Bond StrengthASTM D4541300 psi
Abrasion ResistanceASTM D4060830 mg
MavSeal RCU cure schedule at the conditions printed on the sheet
ConditionDrying Schedule 77°F (25°C)
Foot Traffic3 hours
Full Service24 hours
Maximum Recoat24 hours (@70°F)
  • Theoretical coverage: Wet mils (microns): 16 (406) per coat. Coverage: 100 sq. ft./gal. (2.5 m²/L) per coat. Higher temperatures will shorten pot life and working time.
  • Packaging: 1.5-Gallon Kit: 1 gal Part A : ½ gal Part B.
  • Colors and finish: Clear with a high gloss finish; pigmentable with MavTints by adding one MavTints color pack per 1.5 mixed gallons.
  • Shelf life and storage: 6 months from date of manufacture when stored indoors in the original unopened container at 65°F – 80°F (18°C – 27°C) in a dry location. Do not allow materials to freeze.

Substrate Requirements

Apply only to clean, dry, and sound concrete substrates free of all coatings, sealers, curing compounds, oils, greases, or other contaminants that may negatively affect adhesion. New concrete should be cured a minimum of 28 days; for green concrete, prime with MavPrime MVT. Contaminated concrete must be neutralized or removed, laitance and weak surface layers removed, and the concrete must have a minimum surface tensile strength of 300 psi per ASTM D4541. Mechanically prepare to a CSP 3 – CSP 5 profile per ICRI Guideline 310.2R (equal to 60-grit sandpaper or coarser) and address all surface irregularities, cracks, expansion joints and control joints before application. Do not apply to slabs on grade unless a heavy, unruptured vapor barrier has been installed under the slab; MVT must be 3 lbs. or less per 1,000 sq. ft. in 24 hours per ASTM F1869 and in-situ relative humidity below 75% per ASTM F2170. Outgassing may occur from porous concrete, so apply primer and coating while the substrate temperature is dropping (typically evening), verified with a surface thermometer; double priming greatly reduces outgassing. Prior to applying MavSeal RCU, prime the concrete with MavPrime EP or MavPrime MVT, or install over a Maverick polyurethane flooring system; do not install directly to concrete.

Mixing and Installation

MavSeal RCU is mixed 2 parts A (Resin) to 1 part B (Hardener) by volume. If pigmenting, add one pre-mixed MavTints color pack to Part A per 1.5 mixed gallons. Pour Part B into the Part A pail and mix for a minimum of two minutes with a Jiffy-type mixer at low speed, scraping the sides of the pail because any unmixed material left on the side will not cure. Apply by roller, or by flat or notched squeegee and back-roll with a 3/8" shed-resistant woven roller cover, moving quickly and emptying the pail onto the surface as fast as possible for maximum working time; back-roll lightly if necessary and do not over-roll, which may introduce small air bubbles. Material that gels on top in the pail is not lost, as the underlying material remains usable up to 6 hours after mixing, and once applied at proper mil thickness MavSeal RCU cures like a polyaspartic. Air temperature must be 50° – 80°F and the floor at least 5 degrees above the dew point; pot life is 13 minutes at 77°F and higher temperatures shorten it.

Full step-by-step instructions, pot life and recoat windows are in the MavSeal RCU product data sheet. Maverick installs MavSeal RCU with its own crews.

Specifying MavSeal RCU?

Maverick engineers, manufactures and installs the system. Send the drawings and we will return a scope, a build-up and a quote.